CASE REPORT

A rare case of penetrating lung and cardiac injury due to late migration of multiple Kirschner-wire after shoulder fracture fixation

Ivan Joalsen , Arif Prasetyo Utomo

Ivan Joalsen
Staff of Division of Cardiothoracic and Vascular Surgery, Abdul Wahab Sjahranie General Hospital- Medical Faculty of Mulawarman University, Samarinda, East Kalimantan, Indonesia. Email: [email protected]

Arif Prasetyo Utomo
Staff of Division of Cardiothoracic and Vascular Surgery, Abdul Wahab Sjahranie General Hospital- Medical Faculty of Mulawarman University, Samarinda, East Kalimantan, Indonesia
Online First: February 02, 2020 | Cite this Article
Joalsen, I., Utomo, A. 2020. A rare case of penetrating lung and cardiac injury due to late migration of multiple Kirschner-wire after shoulder fracture fixation. Bali Medical Journal 9(1): 44-46. DOI:10.15562/bmj.v9i1.1461


Introduction: Penetrating foreign body through lung and cardiac is very uncommon case and may lead to life-threatening complication.

Case: We reported an unusual case of penetrating lung and cardiac injury as a complication of open reduction and internal fixation combined with transfixing wire of right glenohumeral procedure.

Conclusion: The Kirschner wires were successfully extracted by using heart-lung machine (HLM) through thoracotomy and sternotomy approach, consecutively.

References

Mazet R. Migration of a Kirschner wire from the shoulder region into the lung: report of two cases. J Bone Joint Surg Am. 1943;25:477-83.

Freund E, Nachman R, Gips H. Migration of a Kirschner wire used in the fixation of a subcapital humeral fracture, causing cardiac tamponade: case report and review of literature. Am J Forensic Med Pathol. 2007;28:155–156.

Gulcan O, Sezgin AT, Bolat B, et al. Right ventricular penetration and cardiac tamponade as a late complication of Kirschner wire placement in the sternoclavicular joint. Interact Cardiovasc Thorac Surg 2005; 4:295–296..

Lyons FA, Rockwood CA Jr. Migration of pins used in operations on the shoulder. J Bone Joint Surg Am 1990;72:1262–7

Wu YH, Lai CH, Luo CY, Tseng YL. Tracheoinnominate artery fistula caused by migration of a Kirschner wire. Eur J Cardiothorac Surg. 2009;36(1):214-6.

Mamane W, Breitel D, Lenoir T, Guigui P. Spinal migration of a Kirschner wire after surgery for clavicular nonunion. A case report and review of the literature. Chir Main. 2009;28(6):367-9.

Nakayama M, Gika M, Fukuda H, Yamahata T, Aoki K, Shiba S, et al. Migration of a Kirschner wire from the clavicle into the intrathoracic trachea. Ann Thorac Surg. 2009;88(2):653-4.